SUDHARSAN equips switchgear and panel factories with routine-test systems that keep pace with production: breaker trip testers, panel insulation withstand units and heavy-current sources for busbar temperature rise. Every panel is tested the same way, and customer witness tests pass the first time.
The test bay keeps pace with production.
Every panel tested the same way.
Witness tests pass the first time.
Kits built to the factory's own ratings.
Pick a test to see where it is done and which SUDHARSAN kit proves it.

2-in-1 breaker test kit

MCB & overload relay kit

HV test transformer

Heavy current source

RCCB / ELCB test kit

Variable DC source
| Test | Where in the factory | SUDHARSAN kit |
|---|---|---|
| MCCB overload and short-circuit release | Final inspection of MCCB feeders | SI/MCB-MCCB: SI/MCB-MCCB 100/2000 (2-in-1) |
| MCB and overload relay trip | MCBs and motor-starter overload relays | SI/MCB-200: 0.01–200 A with timer |
| Panel insulation withstand | Completed LV panels before dispatch | SI/HV series: SI/HV7: 3–10 kV |
| Busbar temperature rise | Busbar systems and type verification | SI/PIK 4000 A: Heavy current source to 4000 A |
| RCCB / ELCB trip | Distribution boards with RCCBs | SI/RCCB-1T: With built-in timer |
| DC trip and closing coils | Control wiring, coils and DC relays | DC 300 V source: 0–300 V DC variable |
Every system is built in-house and tested at 20–100 % of its rating before dispatch. Non-standard ratings are built to order.
SI/MCB-MCCB2-in-1 breaker test kit · MCB & MCCB to 2000 A
SI/MCB-200MCB & overload relay kit · 0.01–200 A with timer
SI/HV seriesHV test transformer · 3–10 kV withstand
SI/PIK 4000 AHeavy current source · Up to 4000 A at 0–5 V
SI/RCCB-1TRCCB / ELCB test kit · 10–600 mA with timer
DC 300 V sourceVariable DC source · Trip & closing coilsInject 1.13 × In (the MCB must hold), then 1.45 × In (it must trip within the conventional time), then the instantaneous multiple for its B, C or D curve. The SI/MCB-200 does all three with a built-in timer.
A one-minute power-frequency withstand between live parts and the earthed frame at the voltage set for its insulation rating: for example, 1.89 kV for 690 V. The SI/HV7 covers this.
Yes. The SI/PIK heavy current source delivers up to 4000 A at 0–5 V and holds it steady until temperatures stabilise.
Send us your product ratings and daily volume, and we will design the bay.
Tell us your application. We’ll engineer the test solution. · Technical: +91 98847 01185 · anirudh@sudharsanelektric.com
IEC standards are cited for the test method only. SUDHARSAN kits follow that method; they are not certified to the standard.