Commissioning tests for solar, wind and battery storage

SUDHARSAN gives renewable EPCs and O&M teams their own test systems for the AC and DC sides of a plant: 33 kV collection cables, inverter and turbine LV breakers, pooling-substation relays and battery DC busbar joints. Testing in-house means fewer outside agencies, and the plant meets its commercial operation date.

  • 33 kV collection cables
  • BESS DC joints
  • Van-portable kits
What we solve

Outcomes for every role on the job

Developer

Commercial operation date met.

EPC team

Cable and breaker tests done in-house.

O&M

Faults found before generation is lost, and joint resistance trended over time.

Lender and owner

Assets proven at handover.

Test-point explorer

Where we test in your plant

Pick a test to see where it is done and which SUDHARSAN kit proves it.

SUDHARSAN SI/EHV-70/80 ac/dc hi-pot kit used for cable insulation withstand
Test point 1 · Cable insulation withstand

SI/EHV-70/80

AC/DC hi-pot kit

Where
33 kV collection cables (solar and wind)
Rating
To 100 kV AC / 120 kV DC
View the SI/EHV-70/80 →
View all test points as a table
TestWhere in the plantSUDHARSAN kit
Cable insulation withstand33 kV collection cables (solar and wind)SI/EHV-70/80: To 100 kV AC / 120 kV DC
Primary injectionInverter-station LT panels, turbine LV breakersSI/PIK-10T: SI/PIK-10: 500–2000 A
Over-current and earth-fault relaysPooling and wind-farm substation relaysSI/CV-30: Briefcase kit: 0.01–30 A
DC busbar joint resistanceBattery racks and DC busbarsSI/MVD-100: 100 A DC
DC trip and closing coilsAuxiliary DC supplies and breaker controlsDC 300 V source: 0–300 V DC variable
FAQ

Frequently asked questions

What test voltage is used for 33 kV solar collection cables?

The test voltage and duration come from the cable specification and the referenced standard (IEC 60502-2*). The SI/EHV-70/80 covers 35–100 kV AC and 45–120 kV DC with a 25 or 50 mA trip.

Do wind service teams need a heavy kit for breaker tests?

No. The SI/PIK-10 and the briefcase SI/CV-30 are built to travel in a service van and test the turbine LV breaker and the substation relays on the same visit.

Why measure battery busbar joints in micro-ohms?

A loose or dirty joint heats up under thousands of amps. Measuring every joint at 100 A DC finds the hot joint before it burns.

Trusted in renewables by
  • Regen Power Tech

Building or maintaining a solar, wind or BESS plant?

Send us your cable and breaker ratings, and we will recommend the kit.

Tell us your application. We’ll engineer the test solution. · Technical: +91 98847 01185 · anirudh@sudharsanelektric.com

WhatsApp +91 96558 62424